Description:
These devices consist of four independent high-gain frequency-compensated operational amplifiers that are designed specifically to operate from a single supply over a wide range of voltages. Operation from split supplies also is possible if the difference between the two supplies is 3 V to 32 V (3 V to 26 V for the LM2902 device), and VCC is at least 1.5 V more positive than the input common-mode voltage. The low supply-current drain is independent of the magnitude of the supply voltage.
Applications include transducer amplifiers, dc amplification blocks, and all the conventional operational-amplifier circuits that now can be more easily implemented in single-supply-voltage systems. For example, the LM124 device can be operated directly from the standard 5-V supply that is used in digital systems and provides the required interface electronics, without requiring additional ±15-V supplies.
Features
1. 2-kV ESD Protection for: LM224K, LM224KA, LM324K, LM324KA, LM2902K, LM2902KV, LM2902KAV
Wide Supply Ranges Single Supply: 3 V to 32 V (26 V for LM2902) Dual Supplies: ±1.5 V to ±16 V (±13 V for LM2902)
Low Supply-Current Drain Independent of Supply Voltage: 0.8 mA Typ Common-Mode Input Voltage Range Includes Ground, Allowing Direct Sensing Near Ground
Low Input Bias and Offset Parameters Input Offset Voltage: 3 mV Typ A Versions: 2 mV Typ Input Offset Current: 2 nA Typ Input Bias Curren: 20 nA Typ A Versions: 15 nA Typ
Differential Input Voltage Range Equal to Maximum-Rated Supply Voltage: 32 V (26 V for LM2902)
Open-Loop Differential Voltage Amplification: 100 V/mV Typ Internal Frequency Compensation
On Products Compliant to MIL-PRF-38535, All Parameters Are Tested Unless Otherwise Noted. On All Other Products, Production Processing Does Not Necessarily Include Testing of All Parameters.
|