Description:• MT2 Series Electrical Characteristics 1. Coil Power Rating Class 300 – 400 mW 2. Actuating System DC 3. Insulation Initial Dielectric Between Open Contacts 750 Vrms 4. Contact Limiting Short-Time Current 2 A 5. Insulation Initial Dielectric Between Contacts and Coil 1050 Vrms 6. Insulation Initial Dielectric Between Coil/Contact Class 1000 V – 1500 VA 7. Voltage Standing Wave Ration (HF Parameter) 1.03 @ 100MHz, 1.31 @ 900MHz 8. Insulation Initial Dielectric Between Adjacent Contacts 750 Vrms 9. Power Consumption 400 mW 10. Insulation Initial Resistance 1000 MΩ 11. Contact Limiting Making Current 2 A 12. Coil Resistance
|
Related Part Number |
5-5330808-6 | 5-5223955-2 5-1462000-5 | |